Shadowclad® Site App

2018 WebsiteImages ShadowcladAPP Phones 825px

The Shadowclad® site application is designed for Building Professionals on the go.

Available on your smartphone the App has been developed to aid in the installation of Shadowclad in accordance with the Shadowclad Specification and Installation Guides.

The App is free to use and can be downloaded from the iTunes App Store or Google Play

Features & Benefits

  • Context-sensitive installation checklist
  • Access to installation details
  • Storage and handling requirements
  • Health & safety information
  • Maintenance requirements;
  • Other key installation requirements

System Requirements

The app can be downloaded from either the iTunes App Store or Google Play: type in the keyword "Shadowclad sITe" to download it, find more information here.

Download on the App Store Badge US UK 135x40 Download on the Google Play Badge US UK 135x40

Sds

Shadowclad SDS H3.2 CCA Treated Plywood

Chemwatch Safety Data Sheet.

Shadowclad SDS Untreated Plywood

Chemwatch Safety Data Sheet.

Shadowclad SDS H3.1 LOSP Treated Plywood

Chemwatch Safety Data Sheet.

Technical Note

Shadowclad Direct Fix BRANZ Appraisal No.765

BRANZ appraisal for Shadowclad direct fixed.

Trouble with Substitutes

Think hard and check before substituting one building product for another. Get it wrong and you could be creating quality issues and have trouble getting a Code Compliance Certificate.

Moulds on Timber

Technical Note relating to moulds on timber.

Product Technical Statement

Shadowclad Direct Fix

Shadowclad Cavity Construction July 2015

Shadowclad® Cavity Construction July 2015

Product Technical Statement for Shadowclad used in Cavity Construction

Brochure

Shadowclad Look Book 2017

See how other architects have leveraged the natural beauty of Shadowclad for high end residential and commercial institutions right the way through to the classic kiwi holiday home.

Shadowclad Specification & Installation Guide For Cavity Construction May 2018

The information in this guide relates to Shadowclad plywood Cladding Installation for Cavity Construction.

Shadowclad Specification & Installation Guide for Mixed Cladding Systems on Cavity Construction May 2018

The information in this guide relates to Shadowclad plywood Mixed Cladding Installation for Cavity Construction.

Information Bulletin

Interior Plywood Range December 2015

Manufactured in New Zealand by Carter Holt Harvey Woodproducts, the Interiors portfolio is a range of untreated plywood panels suitable for internal use as wall and ceiling linings.

Treated Timber and Plywood Hazard Class Quick Guide

Treated timber and plywood hazard class Quick Guide.

Cad

SC001

Typical Framing Setout (without Battens)

SC002

Typical Framing Setout (with Battens)

SC003

Shadowclad - Fastener Layout

SC006

Shadowclad - Texture Vertical Joint (Cavity)

SC008

Shadowclad - Groove Vertical Joint (Cavity)

SC010

Shadowclad - Vertical Joint with Optional Cover Batten (Cavity)

SC012

Shadowclad - Nogging for Vertical Cover Batten Between Studs (Cavity)

SC014

Shadowclad - Vertical Joint with Top Hat Flashing (Cavity)

SC016

Shadowclad - Mid Floor Horizontal Joint (Cavity)

SC018

Shadowclad - Mid Floor Horizontal Joint Non Continuous (Cavity)

SC020

Shadowclad - External Corner with External Box Flashing (Cavity)

SC022

Shadowclad - External Corner with Cover Boards (Cavity)

SC024

Shadowclad - Internal Corner with 90-U Flashing (Cavity)

SC026

Shadowclad - Internal Corner with W Flashing (Cavity)

SC028

Shadowclad - Window Head Detail (Cavity)

SC030

Shadowclad - Jamb Detail (Cavity)

SC032

Shadowclad - Window Sill Detail (Cavity)

SC034A

Shadowclad - Meterbox Vertical Cross Section (Cavity)

SC034B

Shadowclad - Meterbox Horizontal Cross Section (Cavity)

SC036

Shadowclad - Soffit Detail (Cavity)

SC036A

Shadowclad - Alternative Soffit Detail (Cavity)

SC038

Shadowclad - Soffit Alternative Detail (Cavity)

SC038A

Shadowclad - Alternative Soffit Detail (Cavity)

SC040

Shadowclad - Pipe Penetration (Cavity)

SC042

Shadowclad - Overhangs and Ground Clearances (Cavity)

SC044

Shadowclad - Upper Storey to Masonry Lower Storey (Cavity)

SC046

Shadowclad - Timber Ground Floor to Non-Cantilevered Deck (Cavity)

SC048

Shadowclad - Mid Floor to Non-Cantilevered Deck (Cavity)

SC050

Shadowclad - Basic Apron Flashing (Cavity)

SC052

Shadowclad - Balustrade to Wall Junction (Cavity)

SC054

Shadowclad - Balustrade to Wall Junction (Cavity)

SC056

Shadowclad - Junction with Wall for Cantilevered Deck (Cavity)

SC058

Shadowclad - Detailing for Enclosed Balustrade (Cavity)

SC060

Shadowclad® to Weatherboard internal junctions

SC061

Shadowclad® to Weatherboard external junctions

SC062

Shadowclad® to Weatherboard vertical junctions

SC063

Shadowclad® to solid plaster vertical junctions

SC064

Shadowclad® to solid plaster internal junctions

SC065

Shadowclad® to solid plaster external junctions

SC066

Shadowclad® to brick vertical junctions

SC067

Shadowclad® to brick internal junctions

SC068

Shadowclad® to brick external junctions

SC001

Typical Framing Setout - Direct Fix

SC003A

Shadowclad Fastener Layout - Direct Fix

SC004

Shadowclad Texture and Groove Sheet Dimensions - Direct Fix

SC005

Shadowclad Texture Vertical Joint - Direct Fix

SC007

Shadowclad Groove Vertical Joint - Direct Fix

SC009

Shadowclad Vertical Joint with Optional Cover Batten (Direct Fix)

SC011

Shadowclad Nogging for Vertical Cover Batten Between Studs (Direct Fix)

SC013

Shadowclad Vertical Joint with Top Hat Flashing (Direct Fix)

SC015

Shadowclad Mid Floor Horizontal Joint - Direct Fix

SC019

Shadowclad External Corner with External Box Flashing (Direct Fix)

SC021

Shadowclad External Corner with Cover Boards - Direct Fix

SC023

Shadowclad Internal Corner with 90 Degree Flashing - Direct Fix

SC025

Shadowclad Internal Corner with W Flashing - Direct Fix

SC027

Shadowclad Window Head Detail - Direct Fix

SC029

Shadowclad Jamb Detail - Direct Fix

SC031

Shadowclad Window Sill Detail (Direct Fix)

SC031A

Shadowclad General Window and Door Opening - Direct Fix

SC033A

Shadowclad Meterbox Vertical Cross Section - Direct Fix

SC033B

Shadowclad Meterbox Horizontal Cross Section - Direct Fix

SC035

Shadowclad Soffit Detail - Direct Fix

SC036A

Shadowclad Alternative Soffit Detail - Direct Fix

SC037

Shadowclad Alternative Soffit Detail - Direct Fix

SC038A

Shadowclad Alternative Soffit Detail - Direct Fix

SC039

Shadowclad Pipe Penetration - Direct Fix

SC041

Shadowclad Overhangs and Ground Clearances - Direct Fix

SC043

Shadowclad Upper Storey to Masonry Veneer - Direct Fix

SC045

Shadowclad Timber Ground Floor to Non-Cantilevered Deck - Direct Fix

SC047

Shadowclad Mid Floor to Non-Cantilevered Deck - Direct Fix

SC049

Shadowclad Basic Apron Flashing - Direct Fix

SC063

Shadowclad® to solid plaster vertical junctions - Direct Fix

Video

Shadowclad Window Jamb
Shadowclad External Corner with Cover Boards
Shadowclad Flashing Junctions & Connections with Horizontal & Back Flashing
Shadowclad Internal Corner 'W' Flashing
Shadowclad Window Top Flashing
Shadowclad Window jamb & sill
Shadowclad Overhangs & Ground Clearances
Shadowclad External Corner Box Flashings
Shadowclad Vertical Sheet Joint Texture Profile
Shadowclad Horizontal Continuous Flashing
Shadowclad Mid Floor Horizontal Joint
Shadowclad Vertical Sheet Joint Groove Profile